25 psi (1.7 bar) Single Head Fixed Output Pump max 3 gpd (11 lpd)
How It Works
Stenner’s fixed output metering pump is built with two detachable components: the motor and pump head. Outputs are dependent upon the rpm of the motor gears and the size of the peristaltic pump tube. The fixed rate pump has no output adjustment. All Stenner metering pumps have a 3-point roller design in the pump head, which acts as a check valve to prevent back flow, siphoning, overdosing and loss of prime.
The motor’s output shaft rotates at a fixed rpm which drives the roller assembly within the pump head. The chemical solution in the pump tube is captured between the rollers as they rotate and compress the tube. As the rollers advance, the squeezed tube section regains its original form and generates a vacuum, creating the self-priming feature that delivers a constant flow unaffected by the outlet pressure.
Features:
Self-priming up to 25 feet and does not lose prime
Can pump off-gassing solutions
Solutions contained in tube, not exposed to pump components or air
Subassemblies fit together without tools; easy service or conversion to another model
Pump head universal to all Stenner pumps
Can run dry without damage
Will not clog from dirt or debris
Reproducible outputs within 2%
Pump tubes accept a variety of chemicals
Dimensions:

Specifications Summary